Classe de précision | Acier | Dureté à coeur | Dureté sur la denture | Finition de la denture | Faces | parall. | PERP. |
ISO 8 | C45 | <650 N/mm² | <20 HRC | Denture taillée | Brutes d'étirage | 0,06 mm/m | - |
Modules disponibles |
1 - 1.5 - 2 - 3 |
Module | 1 | 1,5 | 2 | 3 |
Erreur de pas individuelle (mm) | ± 0.016 | ± 0.016 | ± 0.016 | ± 0.016 |
Erreur de pas cumulée (mm/m) | < 0.063 | < 0.063 | < 0.063 | < 0.071 |
Module
|
Nb de dents |
L
|
B
|
H
|
Ho
|
I
|
E
|
E'
|
F
|
F'
|
R
|
S
|
T
|
M
|
G
|
O
|
C
|
K
|
J
|
An
|
Références
|
1 | 159 | 499.51 | 15 | 14 | 13 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | FIR-D-1-500 |
1 | 318 | 999 | 15 | 14 | 13 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | FIR-D-1-1000 |
1 | 159 | 499.51 | 20 | 20 | 19 | - | - | - | 124.87 | 249.73 | - | - | - | 2 | 7.5 | 7 | 7 | 11 | - | - | FIR-DL-1-500 |
1 | 318 | 999 | 20 | 20 | 19 | - | - | - | 166.5 | 333 | - | - | - | 3 | 7.5 | 7 | 7 | 11 | - | - | FIR-DL-1-1000 |
1.5 |
106 | 499.47 | 15 | 14 | 12.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | FIR-D-1.5-500 |
1.5 | 212 | 999 | 15 | 14 | 12.5 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | FIR-D-1.5-1000 |
1.5 | 106 | 499.47 | 20 | 20 | 18.5 | - | - | - | 124.87 | 249.73 | - | - | - | 2 | 7.5 | 7 | 7 |
11 |
- | - | FIR-DL-1.5-500 |
1.5 | 212 | 999 | 20 | 20 | 18.5 | - | - | - | 166.5 | 333 | - | - | - | 3 | 7.5 | 7 | 7 | 11 | - | - | FIR-DL-1.5-1000 |
2 | 79 | 496.36 | 20 | 20 | 18 | - | - | - | 124.09 | 248.18 | - | - | - | 2 | 7.5 | 7 | 7 | 11 | - | - | FIR-D-2-500 |
2 | 159 | 999 | 20 | 20 | 18 | - | - | - | 166.5 | 333 | - | - | - | 3 | 7.5 | 7 | 7 | 11 | - | - | FIR-D-2-1000 |
2 | 80 | 508.64 | 25 | 24 | 22 | - | - | - | 62.8 | 125.66 | - | - | - | 4 | 8 | 7 | 7 | 11 | - | - | FIR-DL-2-500 |
2 | 160 | 1005.28 | 25 | 24 | 22 | - | - | - | 62.8 | 125.66 | - | - | - | 8 | 8 | 7 | 7 | 11 | - | - | FIR-DL62-1000 |
3 | 54 | 508.9 | 30 | 29 | 26 | - | - | - | 63.62 | 127.23 | - | - | - | 4 | 9 | 9 | 10 | 15 | - | - | FIR-D-3-500 |
3 | 108 | 1017.9 | 30 | 29 | 26 | - | - | - | 63.62 | 127.23 | - | - | - | 8 | 9 | 9 | 10 | 15 | - | - | FIR-D-3-1000 |
Nbre de dents du pignon
|
Module 1 B=15 |
Module 1 B=20 |
Module 2 B=20 |
Module 2 B=25 |
Module 3 B=30 |
|
21 dents
|
Force transmissible (Ft) (N) | 90 | 120 | 280 | 515 | 1490 |
Couple (T) (Nm) | 0.9 | 1.3 | 4.4 | 11 | 47 | |
Force axiale (Fa) (N) |
-
|
-
|
-
|
-
|
-
|
|
Force radiale (Fr) (N) | 35 | 44 | 100 | 190 | 540 | |
25 dents
|
Force transmissible (Ft) (N) | 140 | 180 | 425 | 770 | 2180 |
Couple (T) (Nm) | 1.8 | 2.3 | 8 | 19 | 80 | |
Force axiale (Fa) (N) |
-
|
-
|
-
|
-
|
-
|
|
Force radiale (Fr) (N) | 51 | 66 | 155 | 280 | 790 | |
30 dents
|
Force transmissible (Ft) (N) | 210 | 270 | 600 | 1130 | 3080 |
Couple (T) (Nm) | 3.2 | 4.1 | 14 | 34 | 140 | |
Force axiale induite (Fa) (N) |
-
|
-
|
-
|
-
|
-
|
|
Force radiale induite (Fr) (N) | 76 | 100 | 220 | 410 | 1120 |
plans 2d (PDF) |
plans 3D (STEP) |